VB编程获得主机域名 Private Const WS_VERSION_REQD = &H101 Private Const WS_VERSION_MAJOR = WS_VERSION_REQD \ &H100 And &HFF& Private Const WS_VERSION_MINOR = WS_VERSION_REQD And &HFF& Private Const MIN_SOCKETS_REQD = 1 Private Const SOCKET_ERROR = -1 Private Const WSADescription_Len = 256 Private Const WSASYS_Status_Len = 128 Private Type HOSTENT hName As Long hAliases As Long hAddrType As Integer hLength As Integer hAddrList As Long End Type Private Type WSADATA wversion As Integer wHighVersion As Integer szDescription(0 To WSADescription_Len) As Byte szSystemStatus(0 To WSASYS_Status_Len) As Byte iMaxSockets As Integer iMaxUdpDg As Integer lpszVendorInfo As Long End Type Private Declare Function WSAGetLastError Lib "WSOCK32.DLL" () As Long Private Declare Function WSAStartup Lib "WSOCK32.DLL" (ByVal _ wVersionRequired&, lpWSAData As WSADATA) As Long Private Declare Function WSACleanup Lib "WSOCK32.DLL" () As Long Private Declare Function gethostbyname Lib "WSOCK32.DLL" (ByVal _ hostname$) As Long Private Declare Sub RtlMoveMemory Lib "KERNEL32" (hpvDest As Any, _ ByVal hpvSource&, ByVal cbCopy&) Function hibyte(ByVal wParam As Integer) '获得整数的高位 hibyte = wParam \ &H100 And &HFF& End Function Function lobyte(ByVal wParam As Integer) '获得整数的低位 lobyte = wParam And &HFF& End Function Sub SocketsInitialize() Dim WSAD As WSADATA Dim iReturn As Integer Dim sLowByte As String, sHighByte As String, sMsg As String iReturn = WSAStartup(WS_VERSION_REQD, WSAD) If iReturn <> 0 Then MsgBox "Winsock.dll 没有反应." End End If If lobyte(WSAD.wversion) < WS_VERSION_MAJOR Or (lobyte(WSAD.wversion) = WS_VERSION_MAJOR And hibyte(WSAD.wversion) < WS_VERSION_MINOR) Then sHighByte = Trim$(Str$(hibyte(WSAD.wversion))) sLowByte = Trim$(Str$(lobyte(WSAD.wversion))) sMsg = "Windows Sockets版本 " & sLowByte & "." & sHighByte sMsg = sMsg & " 不被winsock.dll支持 " MsgBox sMsg End End If If WSAD.iMaxSockets < MIN_SOCKETS_REQD Then sMsg = "这个系统需要的最少Sockets数为 " sMsg = sMsg & Trim$(Str$(MIN_SOCKETS_REQD)) MsgBox sMsg End End If End Sub Sub SocketsCleanup() Dim lReturn As Long lReturn = WSACleanup() If lReturn <> 0 Then MsgBox "Socket错误 " & Trim$(Str$(lReturn)) & " occurred in Cleanup " End End If End Sub Sub Form_Load() '初始化Socket SocketsInitialize End Sub Private Sub Form_Unload(Cancel As Integer) '清除Socket SocketsCleanup End Sub Private Sub Command1_click() Dim hostent_addr As Long Dim host As HOSTENT Dim hostip_addr As Long Dim temp_ip_address() As Byte Dim i As Integer Dim ip_address As String hostent_addr = gethostbyname(Text1) If hostent_addr = 0 Then MsgBox "主机名不能被解释." Exit Sub End If RtlMoveMemory host, hostent_addr, LenB(host) RtlMoveMemory hostip_addr, host.hAddrList, 4 ReDim temp_ip_address(1 To host.hLength) RtlMoveMemory temp_ip_address(1), hostip_addr, host.hLength For i = 1 To host.hLength ip_address = ip_address & temp_ip_address(i) & "." Next ip_address = Mid$(ip_address, 1, Len(ip_address) - 1) MsgBox ip_address End Sub